CONTROL OF ELECTRON BEAM HEATING POWER DISTRIBUTION IN ELECTRON BEAM MELTING OF TITANIUM SLABS
Ye.I. Lipchanchuk 0009-0000-3221-2575, V.O. Berezos
0000-0002-5026-7366, O.H. Yerokhin
0000-0003-2105-5783
- E.O. Paton Electric Welding Institute
Oral Online
Electron beam cold hearth melting (EBCHM) of rectangular titanium slabs represents a highly efficient and promising alternative to traditional vacuum arc remelting (VAR). This technology enables the direct production of slab ingots straight from the liquid phase. Consequently, it effectively eliminates the capital-intensive, multi-stage, and energy-consuming stage of hot forging reduction typically required for round ingots. Furthermore, the implementation of EBCHM ensures a significant reduction in process scrap, increasing the material utilization factor from 0.65 to 0.90.
The primary technological challenge in implementing this method stems from the specific geometry of the mold. The rectangular shape of the liquid metal pool disrupts the radial symmetry of thermal fields and creates a zone of intensive two-dimensional heat extraction into the water-cooled copper walls. The results of computer thermophysical modeling indicate that the local heat flux in the corner zones of the mold is 1.4–1.7 times higher than along the flat sections of its perimeter. Such local thermal supercooling of the melt meniscus leads to premature solidification of the metal shell and poses a risk of severe casting defects, including skull skin folding, deep surface corrugations, and internal diagonal lack-of-fusion defects within the ingot body.
To effectively compensate for edge thermal effects and align the solidification front, a comprehensive series of theoretical and experimental studies was conducted to substantiate, calculate, and optimize the spatial-temporal scanning parameters of the peripheral electron beam. It was established that the optimal compromise between thermal stability and beam movement dynamics is achieved by introducing a controlled technological dwell time of 0.5 s directly into the corner coordinates of the scanning pattern. Operating the peripheral electron beam gun at a total beam power of 54 kW and a local specific peak energy density of 5.48 kW/cm², the proposed algorithm maintains the integrated average power density in the corner zones at a level of 0.82 kW/cm².
Experimental verification and pilot-industrial heats of slab ingots made of the structural Ti-6Al-4V titanium alloy fully confirmed the adequacy of the developed heating control model. The dynamic power distribution ensured a stable thermal balance at the meniscus, guaranteeing the formation of smooth ingot corners completely free of casting defects, corrugations, macrostructural lack-of-fusion defects, and skull-related cold shuts. The developed regime has been implemented into industrial practice for producing high-quality flat products from titanium and its alloys.