RF INDUCTION PLASMA SPHEROIDIZATION OF TITANIUM POWDERS: A COMPARISON OF AXIAL AND PERIPHERAL FEEDING
Mykola Lyutyk 0009-0000-8229-7327
- Klakona Systems LLC, Kyiv, Ukraine
Oral Online
Spherical titanium and titanium-alloy powders are a key feedstock for additive manufacturing (SLM/LPBF, EBM). RF induction plasma spheroidization is among the most productive routes to such powders, yet the way the feedstock is introduced into the plasma jet strongly affects the thermal history of the particle and the product quality, while a systematic comparison of feeding schemes is still lacking.
This work experimentally compares two powder-feeding methods on an industrial 80 kW (~2 MHz) installation equipped with a gas-recirculation system that recovers the plasma-forming Ar/He mixture: axial feeding into the central discharge zone (~9000 K) and peripheral feeding at the plasmatron nozzle exit (~3500 K). Spheroidization of commercially pure titanium and a nominal Ti-6Al-4V alloy of the 25–63 μm fraction was studied while varying the plasma-forming gas composition (92% Ar + 8% H₂ or 40% Ar + 60% He) and the feed rate from 1 to 4 kg/h. Morphology was assessed by SEM; gas content by inert-gas fusion and hot extraction.
Calculations reveal a quantitative difference in thermal conditions: the full thermal cycle of a 50 μm particle is 5.7×10⁻⁴ s (~3% of the residence time in the active zone) for axial feeding versus 5.3×10⁻³ s (~26%) for peripheral feeding, which sets a different processing-time margin and sensitivity of the process to the feeding regime.
Both methods achieve sphericity ≥95% provided the feed rate is matched to the thermal capacity of the introduction zone; exceeding the critical feed rate (4 kg/h for peripheral feeding) yields only partial spheroidization. A hierarchy of gas media was established: Ar+H₂ outperforms Ar+He in surface quality and satellite minimization; processing in Ar+H₂ reduces the hydrogen content by 68.6% (from 0.0443 to 0.0139 wt.%). A Ca-gettering mechanism was confirmed as a means of lowering the O₂ and N₂ content in the reaction-chamber atmosphere.
The feeding method also governs the electrophysical stability of the "probe–discharge" system: with axial feeding in molecular gases, the frequency of probe arcing rises by more than an order of magnitude. A shutdown mechanism specific to axial feeding was identified — screening of the inductor field by an electrically conductive condensate of powder thermal-decomposition products; peripheral feeding is fundamentally free of this effect.
The results enable a justified choice of feeding scheme and operating regimes depending on the material and product requirements, and indicate the advantages of peripheral feeding for process stability.