← Mathematical Modeling of Welding and Related Processes

Numerical modelling of anode processes in an electric arc with convectively evaporating anode

Andrii Momot1 0000-0001-8162-0161, Igor Krivtsun1 0000-0001-9818-3383, Uwe Reisgen2 0000-0003-4920-2351, Oleg Mokrov2 0000-0002-9380-6905, Rahul Sharma2 0000-0002-6976-4530

  1. 1E.O. Paton Electric Welding Institute, Kyiv, Ukraine
  2. 2Welding and Joining Institute, RWTH Aachen University, Aachen, Germany

Oral in Person

A mathematical model of the anode processes in an atmospheric pressure electric arc has been developed and numerically analyzed for a copper anode evaporating in a convective mode. Under convective evaporation conditions, the plasma is treated as a single-element system composed of electrons and heavy particles of the anode metal (neutral atoms and singly charged ions). The theoretical framework relies on the assumption of a hierarchy of characteristic length scales (distances from the anode surface): the Debye length is significantly smaller than the electron mean free path for elastic collisions with heavy particles, which in turn is much smaller than the electron-impact ionization length of neutral atoms. According to this spatial hierarchy, the anode boundary region is structured into a space-charge sheath, a quasi-neutral plasma in both ionization and thermal non-equilibrium, and a bulk equilibrium plasma of the arc column.

In contrast to conventional anode boundary layer models where inner boundary conditions are imposed at the sheath edge, in the present approach boundary conditions are set at a distance from the anode surface of about the electron mean free path for elastic collisions with the heavy particles. Utilizing the fact that electrons are collisionless and Boltzmann-distributed up to this distance, a novel boundary condition demanding the mathematical smoothness of the electric potential is formulated. At the outer boundary adjoining the arc column, conventional boundary conditions are applied.

Using the proposed model, key parameters of the anode boundary layer were calculated for current densities of (1 – 3) 10^8 A/m2 across various values of copper anode surface overheating relative to the boiling point. The spatial distributions of the number densities and diffusive flux densities of electrons, ions, and atoms; the electron temperature and the heavy particle temperature; and the electric potential were calculated. The dependencies of the anode potential drop on current density and anode surface temperature are presented. Additionally, the total heat transferred from the arc plasma to the anode surface was evaluated, revealing that intense evaporation significantly modifies the energy balance of this surface.

An increase in anode surface temperature drives a substantial rise in mass-average flow velocity and pressure in the arc column. When the anode surface temperature exceeds a critical threshold (overheating above 50 K), the model predicts a net ion ejection from the surface. Such a situation is non-physical and indicates that the arc cannot exist under such surface overheating.